Products >> LITAFLEX

uPVC AIR-CON TRUNKING

Manufactured from an extra High Impact grade of uPVC, LITAFLEX Air-Conditioning Trunking is Fire Resistant rated and complies with the Singapore Standard SS 275: 1999.

To facilitate distribution from the outdoor Air-Conditioning Condensing unit to the Fan Coil Unit mounted on the wall of the living room, LITAFLEX has intelligently designed this non-corrosive Trunking system to secure Electrical Cables, Insulation Tubes containing Copper Tubes and uPVC Drain Pipes.

LITAFLEX's latest NEW design on the base and 'snap-on' lids provides a stronger grip, easy installation and removal for maintenance. The unique characteristics of its clean and smooth curvy edges, strength and durability allows it to be used even on rough wall surfaces and ceilings.

What is more, LITAFLEX's air-conditioning Trunking is extremely weater resistant, which ensures good looks.

Singapore Standard SS 275 : 1999

Standard Length: 2.44M
Colour: WHITE

Installation of Capacity of Multi Split Unit Air-Conditioning System
Test Specification for Cable and Air-Conditioning Trunking Made of Insulating Material
Clause Test Required
Mechanical Properties
Cable Supporting Test for surface mounting

Temperature
Duration
Distortion (Max)



60 ± 2°C
2 hr
10%
Impact Test

Precondition
Duration
Test Temperature
Mass of Hammer
Height of Impact


60 ± 2°C
240 hr
15°C
2 kg
100 mm
Cover Retention Test

Mass attached to Cover
Duration of Test


2 kg
60 sec
Resistant to Heat

Testing Temperature
Applied force of Ball Pressure
Duration of Test
Diameter of impression
Test Required

60 ± 2°C
20 N
1 hr
< 2 mm
Resistance to Flame Propagation

Flame Test


Does not ignite or flames. Self extinguished within 30s after removal of flame.
Insulating Characteristics

Electric Insulating Strength Test

Applied Voltage
Duration of Electrification




2500 V
1 min
Insulation Resistance test
Applied Voltage
Duration of Electrification

500 V dc
1 min
 
 

 